UPS vektor 6kva dengan sistem online dan sudah 3phase sangat cocok untuk kebutuhan perbankan dalam kelistrikan sehingga dapat memback up sekitar 5 s/d 30menit untuk 15 sd 20 computer
kami memberikan garansi 1tahun full service dan sparepart dan termasuk batry dll
kami memberikan after sales free pemasangan dan instalasi untuk daerah tertentu
memberian layanan door to door untuk area2 yang di jangkau dari kantor kami
sehingga tidak perlu repot2 kirim bila ada kerusakan
setelah masa garansi habis kami tetap memberikan pelayanan perbaikan
Vac
- Frequency : 45-65 Hz
- Phase / Wire : Single, Line + Neutral +
Ground - Power Factor : Up to 0.99 at 100% Linear
Load - Current THD : < 5% at 100% Linear
Load
Voltase Keluar
Voltage : 200/220/230/240 Vac Selectable [208/120 Vac Optional]
Voltage Adjustment : Nominal +1%, +2%, +3%, -1%, -2% or -3%
adjustable
Voltage Regulation : +/- 2%
Capacity : 6000VA/4800W
Rated Power Factor : 0.8 lagging
Wave From/Distortion : Sine Wave, Voltage THD <3% [no load to full
load]
Frequency Stability : +/- 0.2% On Inverter Free-Running Mode
Frequency Regulation : +/-1Hz, +/-3Hz [programmable by user]
Transfer Time : 0msec
Crest Factor : 3:1 acceptable
Efficiency [AC to AC, Normal] : Up to 91%
Efficiency [AC to AC, ECO Mode] : Up to 98%
Autonomy [Built-in Battery] : 15-30 mins depending on Load
DC Start : Yes
Baterai Type : Sealed Lead
Acid Maintenance Free 12V/7Ah [Built-in]
- Quantity : 20 pcs
- Voltage : 240 Vdc
- Recharger Time : 4 Hours to 90%
- Supplementary charger : Optional 1000w
isolated Charger
Antarmuka / Interface Interface Type :
Standard RS232 Interface
- Communication slots : 2nd RS232 with EPO, USB
with EPO, RS485 with EPO, Relay contact & EPO, SNMP/WEB Card, etc
[Optional]
Lain-lain Display
- Status
on LED+LCD : Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery
Low, Battery Bad/Disconnect, Overload, Transferring with Interruption,
& UPS Fault - Reading
on LCD : Input Voltage, Input Frequency, Output Voltage, Output
Frequency, Load Percentage, Battery Voltage & Inner
Temperature - Self-Diagnostics
: Upon Power-on & Front Panel Setting
- PROTECTION
- Overload
(with simulated thermal tripping I-T curve) : Inverter Supply: 105%-150%
for 160 seconds- 2cycles [40 min/sec] before switching to bypass, Bypass
Supply: 105%-200% for 500 seconds – 8 cycles before stopping supply
load - Short
Circuit : Inverter Switch off immediately - Overheat
: AC mode : switch off the UPS - Battery
Low : Backup mode : switch off the UPS, alarm and switch off - Noise
Suppression : Complies with EN50091-2 - Spike
Suppression : Complies with EN6100-4-5
- ALARMS
- Audible
and Visual : Line Failure, Battery Low, Transfer to Bypass, System Fault
Condition
- ENVIRONMENT
- Operating
Temperature : 0C – 40C - Altitude
: 0-2000m up to 40C, 3000m up to 35C - Humidity
: 90% RH Maximum, Non-Condensing - Noise
: < 50 dB [at 1 meter] - Dimensi
290 x 645 x
748mm